Reverse Laminar Air Flow Unit Specification

  • Power Consumption
  • 230VAC Volt (V)
  • Lighting
  • UV-FL
  • Filter Type
  • HEPA Filter
  • Voltage
  • 230 Volt (v)
  • Frame Material
  • Stainless Steel
  • Type
  • Other
  • Material
  • Stainless steel
  • Filters
  • BOX TYPE
  • Dimension (L*W*H)
  • 1220X1220X1830 Millimeter (mm)
  • Weight
  • 300 Kilograms (kg)
  • Air Volume
  • 15 Meter/second (m/s)
  • Application
  • USED IN PHARMACEUTICAL INDUSTRIES, PASSING RAW MATERIAL
  • Air Flow
  • 90FPM ft3/min (CFM)
 

Reverse Laminar Air Flow Unit Trade Information

  • Minimum Order Quantity
  • 1 Millimeter
  • Payment Terms
  • Cash in Advance (CID), Cheque
  • Supply Ability
  • 1 Millimeter Per Week
  • Delivery Time
  • 1 Week
  • Main Domestic Market
  • All India
  • Certifications
  • ISO,IEC
 

Reverse Laminar Air Flow Unit About

USED IN PHARMACEUTICLAS INDUSTREIS,

Minimum Order Quantity 1 Piece
Brand SR AIR SYSTEM
Usage/Application PHARMACEUTICAL INDUSTRIES
Material 304-SS
Air Flow Vertical
Model Name/Number SRAS - 2022
Size AS PER STD
Height 7.5 feet
Color SILVER
Lighting Type LED
Power 230VAC
MOC 304-stainless steel
Shape RECTANGULAR
Wall Thickness 40mm
Blower V 2800 RPM
Dimension Mm 910W X 610D X 1830H MM
Efficiency 99.999
Electrical Supply V 1 PHASE
Filtration Capacity Microns 0.3MICRON
Filtration Grade H14
Iso Certified YES
Pre Filter 10 MICRON
Voltage V 230VAC
Weight G 200KG
Air Velocity M Per S 15-20
Country of Origin Made in India


We Deal In Sampling Booth. it is used in pharmaceutical industries and laboratory.We are one of the best manufacturers in this industry.

Dispensing booth isa kind of laminar flow filtration cabin which is employed in dispensing, sampling and weighing of powders and chemicals in pharma, biotech and chemical industries.


Additional Information:

  • Production Capacity:max
  • Delivery Time:12days



Engineered for Sterile Environments

Built with high-grade stainless steel, the unit guarantees durability and hygiene crucial in pharmaceutical industries and hospitals. The HEPA filter system removes airborne contaminants efficiently, protecting sensitive processes and materials.


Efficient Air Management System

With an advanced reverse laminar airflow design and a velocity of 90FPM, this unit ensures consistent air quality. The box-type filters and UV-fluorescent lighting provide extra layers of purification, maintaining a sterile workspace for handling critical raw materials.

FAQs of Reverse Laminar Air Flow Unit:


Q: How does the Reverse Laminar Air Flow Unit operate in pharmaceutical environments?

A: The unit creates a sterile air zone by pushing clean air over work surfaces, capturing contaminants with its HEPA filters. Its reverse laminar flow pattern ensures raw materials remain untainted during handling and processing.

Q: What are the main benefits of using this unit in hospitals or pharmaceutical industries?

A: This unit minimizes cross-contamination, preserves product integrity, and enhances safety by providing a controlled, contaminant-free environment. Its UV lighting further disinfects surfaces, making it ideal for raw material transfer operations.

Q: When should this unit be serviced or its filters replaced?

A: HEPA filters generally require inspection and possible replacement every 6 to 12 months, depending on usage and contamination levels. Regular service checks ensure optimal performance and continued air quality.

Q: Where is the Reverse Laminar Air Flow Unit best installed?

A: It should be installed in cleanrooms, pass-through areas, and material transfer zones within pharmaceutical production facilities and hospital laboratories where sterile conditions are mandatory.

Q: What is the process for handling raw materials with this unit?

A: Raw materials are placed within the units containment zone, where airflow and filtration systems continuously remove particulates. UV light aids in disinfecting the handling area, ensuring materials remain uncontaminated throughout the transfer process.

Q: How does the stainless steel frame contribute to the units performance?

A: The stainless steel frame adds durability, resists corrosion, and permits easy cleaning. It supports the strict hygiene standards required in medical and pharmaceutical settings, thereby extending the lifespan of the unit.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laminar Air Flow Category

Ceiling Suspended Laminar Air Flow Unit

Ceiling Suspended Laminar Air Flow Unit

Price 50000 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless steel

Application : Pharmaceutical Industry

Voltage : 230 Volt (v)

Condition : New

OT Room Laminar Air Flow

OT Room Laminar Air Flow

Price 27000 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless steel

Application : Industrial

Voltage : 230V / 415V, 50Hz

Condition : New

Industrial Horizontal Laminar Air Flow

Industrial Horizontal Laminar Air Flow

Price 65000 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless steel

Application : Laboratory

Voltage : 240 Volt (v)

Condition : New

MS Vertical Laminar Air Flow

MS Vertical Laminar Air Flow

Price 62500 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Other

Application : Laboratory

Voltage : 230 Volt (v)

Condition : New



"We are mainly dealing in Gujarat."
Back to top